• Installation of the system for ultrasonic flow measurement in the tunnel diameter of Ø6000mm:
-Manufacturer: Accusonic Technologies Inc.;
-Flow meter series 7510;
-Temperature (working): 0-40o C;
-Water characteristics:
-pH: 3,5 to 10
-Solids loading rate: 0-2000 parts/million;
-Evaporation of ketones and esters must not be present.
-Acoustic paths: max 8;
-Permament display of data: LCD, two rows by 20 alfa-numerics signs
(hight 9mm);
-Entrance level: 4-20 mA (0,4-2 V);
-Analog output: 4-20 mA;
-The cable for the converter: Pair - Axial RG22;
-Hand terminal: TT-8045.
Investor: HET, Trebinje
Total value of project: DEM 65.000